Earth-Rite FIBC Technology:
- LED indicators informing the operator if the FIBC bag to be protected from static discharges is correctly grounded,
- when the system is not in use, or when it detects the resistance in the static dissipative loop is higher than 1 x 10^8 ohms, a red LED illuminates the indicator panel located in the SDP indicator station,
- the system can be setup to physically prevent FIBC filling/emptying operations (interlock) if the bag is not grounded,
- if the resistance of the bag rises above the recommended level of 1 x 10^8 ohms the process can be halted.
Specifications:
- ATEX certificates:
- monitoring system: Ex II 1 GD EEx [ia] IIC T4,
- power supply / interface: Ex II 1 GD EEx [ia] IIC T4, Ex II 1 GD Eex d IIB T5,
- Power supply: 230V or 110V ± 10%, 50 Hz,
- Pre-set electrical resistance: 1 x 10^8 Ω (100 megohms),
- System components: monitoring unit with earth status indicator LEDs, holder for clamp storage, power supply unit with interlock for filling/emptying operations, special monitoring clamp complete with hytrel covered spiral cable.
Options:
- earthing clamp for flexible materials.